PRATT AND LAMBERT INC -- PRIM EPOXY CTG CORRINHIB LD CHR FR ID724700 -- 8010-01-193-0516
===================== Product Identification =====================
Product ID:PRIM EPOXY CTG CORRINHIB LD CHR FR ID724700
MSDS Date:10/26/1988
FSC:8010
NIIN:01-193-0516
Kit Part:Y
MSDS Number: BHYLK
=== Responsible Party ===
Company Name:PRATT AND LAMBERT INC
Address:16116 E 13TH ST
Box:2153
City:WICHITA
State:KS
ZIP:67201
Country:US
Info Phone Num:316-733-1361
Emergency Phone Num:316-733-1361
Preparer's Name:W.A. ELLISON
CAGE:61196
=== Contractor Identification ===
Company Name:PRATT AND LAMBERT INC
Box:6027
City:CLEVELAND
State:OH
ZIP:44101-1027
Country:US
Phone:216-566-2902
CAGE:61196
============= Composition/Information on Ingredients =============
Ingred Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293
Ingred Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192
Ingred Name:PROPYLENE GLYCOL MONOMETHYL ETHER
CAS:107-98-2
RTECS #:UB7700000
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
Ingred Name:METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)
CAS:78-93-3
RTECS #:EL6475000
OSHA PEL:200 PPM/300 STEL
ACGIH TLV:200 PPM/300STEL 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:N-BUTYL ALCOHOL (SARA III)
CAS:71-36-3
RTECS #:EO1400000
OSHA PEL:100 PPM
ACGIH TLV:S, C 50 PPM; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:VOC. ORGANIC CMPD 4.0 LB/GL LESS WATER & NPRS 480 G/L
LESSWATER VOC 9.6 LB/GAL SOLIDS 1152 G/L SOLIDS CALCULATED.
RTECS #:9999999VO
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SWALLOWING: CAN CAUSE GASTROINTESTINAL
IRR/ NAUSEA/VOMIT. ASPIRATION OF MAT'L MAYCAUSE CHEM PNEUMONITIS.
INHALATION: NOSE/THROAT IRRITA. HIGH CONCENTRATION MAY CAUSE
CENTRAL NERVOUS SYSTEM DEPRESSION CHAR BY
HEADACHES/DIZZINESS/NAUSEA/ CONFUSION. EYE: MAY CAUSE EYE IRRITA.
SKIN: MAY CAUSE DEFATTING AND IRRITATION.
Explanation of Carcinogenicity:TITANIUM DIOXIDE IS NOT LISTED AS A
POTENTIAL CARCINOGEN BY THE NTP, IARC, OSHA AND ACGIH.
Effects of Overexposure:REPORTS HAVE ASSOCIATED PROLONGED AND REPEATED
OCCUPATIONAL OVEREXPOSURE TO SOL-VENTS WITH PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING AND INHALING THE CONTENTS MAY BE HARMFUL OR FATAL.
OVEREXPOSURE TO TOLUENE MAY CAUSE LIVER DAMAGE AND CONTACT MAY
CAUSE DERMATITIS.
======================= First Aid Measures =======================
First Aid:SWALLOWING: DO NOT INDUCE VOMITING/GET MED ATTN. INHALATION:
REMOVE TO FRESH AIRIF BREATHING HAS STOPPED GIVE CPR. GET MED ATTN.
EYE: FLUSH W/WATER FOR 15 MIN LIFTING UPPER/LOWER LIDS. GET MED
ATTN. S KIN: REMOVE CONTAMINATED CLOTHING. WASHAFFECTED AREA.
OBTAIN MED ATTN IF IRR'N PERSISTS. TREATMENT REQ FOR OVER- EXPOSURE
S/B DIRECTED AT THE CONTROL OF SYMPTOMS AND THE CLINICAL
CONDITIONS.
===================== Fire Fighting Measures =====================
Flash Point:24F -4.44C
Extinguishing Media:USE NFPA CLASS B FIRE EXTINGUISHERS. POLYMER FOAM
IS PREFERRED FOR LARGE FIRES.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS. WATER
TO COOL CONT TO PREVENT POSSIBLE AUTO-IGNITION OR EXPLOSION. IF
WATER IS USED, FOG NOZZLES ARE PREFERABLE.
Unusual Fire/Explosion Hazard:DURING EMERGENCY CONDITIONS, OVEREXPOSURE
TO DECOMPOSITION PRODUCTS MAY CAUSE A HEALTH HAZARD. SYMP MAY NOT
BE IMMED APPARENT. GET MED ATTN. WARNING! FLAMMABLE
================== Accidental Release Measures ==================
Spill Release Procedures:ELIM ALL IGNITION SOURCES. DIKE/CONTAIN SPILL
WITHINERT MAT'L. TRANSFER LIQ'S/ABSORBENT DIKING MAT'LIN COVERED
METAL CONT'S FOR RECOVERY/DISPOSAL. USEONLY NON-SPARKING TOOLS.
PREVENT CONTAM OF SEWERS/ STREAMS/GROUNDWATER W/SPILLED MAT'L/USED
ABSORBENT
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 90 DEGREES F.
Other Precautions:AVOID SKIN CONTACT. DO NOT REUSE EMPTY CONT. DO NOT
TAKE INTERN. CONT'ER S/B GROUNDED AND BONDED TO THE RECEIVING
CONTAINER. DO NOT WELD/BRAZE OR CUT CONT'R.NEVER USE PRESSURE TO
EMPTY. DRUM IS NOT A PRESSURE VESSEL. CLOSE AFTER EA USE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WELL VENTILATED AREA-RESP NOT REQ. RESTRICTED
VENT-NIOSH CHEMICAL CARTRIDGE MAY BE REQ. IF SPRAYING, MECH
PREFILTER MAY BE REQ. IF TLV ARE EXCEEDED, USE A PROP FITTED
NIOSH/MSHA RESP W/APPROP PROTECTI ON FACTOR. SEE OSHA 29 CFR
1910.134.
Ventilation:PROVIDE DILUTION/LOCAL EXHAUST VENTILATION TO KEEP
CONCENTRAOF HAZARDOUS SUBSTANCES BELOW EXPOSURE LIMITS STATED.
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:WEAR SAFETY SPECTACLES.
Other Protective Equipment:EYEWASH FACILITY, SAFETY SHOWER.
Work Hygienic Practices:WASH WITH SOAP AND WATER HANDS/FACE THROUGHLY
BEFORE EATING OR DRINKING.
Supplemental Safety and Health
NK
================== Physical/Chemical Properties ==================
HCC:F2
Boiling Pt:B.P. Text:175F 248F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER.
Percent Volatiles by Volume:57
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:NO
STRONG ACIDS OR ALKALINE MATERIALS. OXIDIZING MATERIALS. ACCELERATORS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT AND SOURCES OF
IGNITION.
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING OR CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE AND CARBON
DIOXIDE.
Conditions to Avoid Polymerization:KEEP AWAY FROM HEAT, SPARKS AND
FLAME.
==================== Disposal Considerations ====================
Waste Disposal Methods:INCINERATE ONLY IN EPA PERMITTED FACILITY.
DISPOSEONLY IAW FED/STATE/LOCAL REGS. DO NOT INCINERATE CLOSED
CONTAINERS. OBSERVE PRECAUTIONS FOR DIS- POSAL OF FLAMMABLE MAT'S.
CONTAMINATED ABSORBENT MAY BE DISPOSED IN A HAZARDOUS WASTE
LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.