N/P -- PRIMER ELECTROSTATIC EPOXY POLYAMIDE -- 8010-00-142-9279
Product ID:PRIMER ELECTROSTATIC EPOXY POLYAMIDE
MSDS Date:01/01/1987
FSC:8010
NIIN:00-142-9279
Kit Part:Y
MSDS Number: BLJGB
=== Responsible Party ===
CAGE:61196
=== Contractor Identification ===
Company Name:PRATT AND LAMBERT INC
Box:6027
City:CLEVELAND
State:OH
ZIP:44101-1027
Country:US
Phone:216-566-2902
CAGE:61196
============= Composition/Information on Ingredients =============
Ingred Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 20%
Other REC Limits:NONE SPECIFIED
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:ETHYL BENZENE (SARA III)
CAS:100-41-4
RTECS #:DA0700000
Fraction by Wt: <5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:100 PPM/125 STEL
ACGIH TLV:100 PPM/125STEL 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:STRONTIUM CHROMATE (SARA III)
CAS:7789-06-2
RTECS #:GB3240000
Fraction by Wt: 20%
Other REC Limits:*MG/CU M
OSHA PEL:0.1 PPM CRO3;CEILING
ACGIH TLV:0.0005MG CR/M3;A2;93
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Ingred Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: 5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293
Ingred Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: 10%
Other REC Limits:NONE SPECIFIED
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192
Ingred Name:SILICA, CRYSTALLINE - QUARTZ
CAS:14808-60-7
RTECS #:VV7330000
Fraction by Wt: <1%
Other REC Limits:NONE SPECIFIED
OSHA PEL:SEE TABLE Z3
ACGIH TLV:0.1 MG/M3 RDUST;9293
Ingred Name:SILICA, AMORPHOUS-HYDRATED
CAS:63231-67-4
RTECS #:VV7340000
Fraction by Wt: 5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:6 MG/CU M
ACGIH TLV:10 MG/CU M
Ingred Name:METHYL ISOBUTYL KETONE (SARA III)
CAS:108-10-1
RTECS #:SA9275000
Fraction by Wt: 10%
Other REC Limits:NONE SPECIFIED
OSHA PEL:100 PPM/75 STEL
ACGIH TLV:50 PPM/75 STEL; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:VOC: 4.19 LB/GAL LESS WATER & NPRS (NEGLIGIBLY
PHOTOCHEMICALLY REACTIVE MATERIALS) 503 G/L LESS WATER (CALCULATED)
RTECS #:9999999VO
Other REC Limits:NONE SPECIFIED
Ingred Name:VOC: 10.30 LB/GAL SOLIDS; 1236 G/L SOLIDS (CALCULATED)
RTECS #:9999999VO
Other REC Limits:NONE SPECIFIED
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES
Health Hazards Acute and Chronic:ACUTE: INGEST: GASTROINTESTINAL IRRIT,
NAUSEA, VOMIT. ASPIRATION OF MATR'L INTO LUNG MAY CAUSE CHEMICAL
PNEUMONITIS. INHAL: NOSE/THROAT IRRIT, CENTRAL NERVOUS SYSTEM
DEPRESSION. EYE: SEVERE IRRIT. SKI N: SENSITIZATION (ALLERGIC
REACTION), DEFATTING AND IRRIT. CHRONIC: SILICOSIS, INJURY TO
LIVER, KIDNEYS, & BLOOD,*
Explanation of Carcinogenicity:CHROMIUM & CERTAIN CHROMIUM
COMPOUNDS--POTENTIAL CARCINOGENS(NTP). IARC LISTS CRYSTALLINE
SILICA (LIMITED CARCINOGEN).
Effects of Overexposure:HEADACHES, DIZZINESS, NAUSEA AND CONFUSION.
METAL OXIDES MAY RESULT IN "METAL FUME FEVER" SYMPTOMS--A FLU-LIKE
ILLNESS W/FEVER, CHILLS, & COUGH.
*DERMATITIS, PERMANEN T BRAIN AND NERVOUS SYSTEM DAMAGE. DELIBERATE
MISUSE BY CONCENTRATING AND INHALING THE CONTENTS MAY BE HARMFUL OR
FATAL.
Medical Cond Aggravated by Exposure:PREEXISTING RESPIRATORY CONDITIONS
MAY BE AGGRAVATED.
======================= First Aid Measures =======================
First Aid:INGESTION: DON'T INDUCE VOMITING. CALL POISON CONTROL CTR,
HOSPITAL EMERGENCY ROOM/DOCTOR IMMED. INHALATION: REMOVE TO FRESH
AIR IMMED. NOT BREATHING--GIVE ARTIFICIAL RESPIRATION. KEEP WARM &
QUIET. G ET MED AID IMMED. EYE: FLUSH W/LRG AMTS--WATER (15 MIN),
OCCASIONALLY LIFTING LIDS APART. GET MED AID. SKIN: REMOVE
CONTAMINATED CLOTHING. WASH W/SOAP & WATER. IF IRRITATION
PERSISTS--GET MED AID.
===================== Fire Fighting Measures =====================
Flash Point:40.0F,4.4C; CALC
Autoignition Temp:Autoignition Temp Text:572 F
================== Accidental Release Measures ==================
Spill Release Procedures:NO SPECTATORS. REMOVE IGNITION SOURCES. DIKE &
CONTAIN SPILL WITH INERT MATERIAL (SAND/EARTH/ETC). TRANSFER
LIQUIDS TO COVERED METAL CONTAINERS. PREVENT CONTAMINATION OF
SEWERS, STREAMS & GROUNDWATER W/SPILLED MATERIAL OR USED
ABSORBENT.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 90 F.
Other Precautions:DO NOT INGEST. CLOSE CONTAINER AFTER USE. KEEP AWAY
FROM CHILDREN. DO NOT BREATHE SANDING DUST. AVOID SKIN CONTACT.
DON'T WASH OR REUSE EMPTY CNTNRS.CONTAINERS SHOULD BE GROUNDED &
BONDED TO RECEIVIN G CNTNR. DO NOT WELD, BRAZE OR CUT *
============= Exposure Controls/Personal Protection =============
Respiratory Protection:RESTRICTED VENT--NIOSH APPROVED CHEMICAL
CARTRIDGE RESPIRATOR. IF SPRAYING A MECHANICAL PREFILTER MAY BE
REQUIRED. IF TLV ARE EXCEEDED USE A NIOSH/MSHA APPROVED RESPIRATOR
WITH AN APPROPRIATE PROTECTI ON FACTOR. SEE OSHA 29 CFR 1910.134.
Ventilation:GEN DILUTION/LOCAL EXHAUST--SUFF TO KEEP CONC--HAZARD
INGRED BELOW LEL. VENT SMOKE FROM WELD/CUT/BRAZING COATED MATR'L.
Protective Gloves:SOLVENT IMPERMEABLE GLOVES
Eye Protection:SAFETY SPECTACLES
Other Protective Equipment:EYEWASH FACILITY, SAFETY SHOWERS
Supplemental Safety and Health
*ON EMPTY CONTAINER. NEVER USE PRESSURE TO EMPTY. DRUM IS NOT A
PRESSURE VESSEL.
================== Physical/Chemical Properties ==================
Viscosity:>200 CST
================= Stability and Reactivity Data =================
Hazardous Decomposition Products:BURNING, WELDING, CUTTING--MATERIALS
COATED W/THIS PROD--WILL PRODUCE SMOKE, CO2, CO, OXIDES OF
CHROMIUM, METAL OXIDES.
Conditions to Avoid Polymerization:HAZARDOUS POLYMERIZATION MAY OCCUR
WITH THE ADDITION OF EXCESS HARDENER.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORD W/FED/STATE/LOCAL LAWS.
INCINERATE IN EPA PERMITTED FACILITY. DON'T INCINERATE CLOSED
CNTNRS. FOLLOW PRECAUTIONS FOR DISPOSAL OF FLAMMABLE MATERIALS.
DISPOSE OF CONTAMINATED ABSORBEN T IN HAZARDOUS WASTE LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.