DEVOE COATINGS CO -- 137C0910, DEVGRIP 137 CONVERTER FOR EPOXY (SUPDAT) -- 8010-00N027582
===================== Product Identification =====================
Product ID:137C0910, DEVGRIP 137 CONVERTER FOR EPOXY (SUPDAT)
MSDS Date:11/24/1992
FSC:8010
NIIN:00N027582
MSDS Number: BYGGK
=== Responsible Party ===
Company Name:DEVOE COATINGS CO
Address:4000 DUPONT CIR
City:LOUISVILLE
State:KY
ZIP:40207
Country:US
Info Phone Num:502-897-9861
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:DO196
=== Contractor Identification ===
Company Name:DEVOE AND RAYNOLDS CO DIV OF GROW GROUP INC
Address:4000 DUPONT CIR
Box:7600
City:LOUISVILLE
State:KY
ZIP:40207
Country:US
Phone:502-361-2536/502-589-9340
CAGE:6R552
Company Name:DEVOE COATINGS COMPANY
Address:4000 DUPONT CIRCLE
Box:7600
City:LOUISVILLE
State:KY
ZIP:40207
Phone:502-897-9861, CHEMTREC 800-424-9300
CAGE:DO196
============= Composition/Information on Ingredients =============
Ingred Name:ING 6: WHEN NOT IN USE.
RTECS #:9999999ZZ
Ingred Name:RESP PROT: WHEN USED IN RESTRICTED VENT AREAS, WEAR
NIOSH/MSHA APPRVD CHEM/MECH FILTER DESIGNED TO REMOVE A (ING 9)
RTECS #:9999999ZZ
Ingred Name:ING 8: COMBINATION OF PARTICULATES & VAP. WHEN USED IN
CONFINED AREAS, WEAR NIOSH/MSHA APPRVD AIR SUPPLY RESPS (ING 10)
RTECS #:9999999ZZ
Ingred Name:ING 9: OR USE HOODS. USE NIOSH/MSHA APPRVD RESP WHEN FLAME
CUTTING, WELDING, BRAZING & SANDING MATL COATED W/THIS PROD.
RTECS #:9999999ZZ
Ingred Name:VENT: SAFETY & HLTH STDS IN MIXING, APPLICATION & CURING
AREAS & TO REMOVE SANDING DUSTS OF DRIED COATINGS & (ING 12)
RTECS #:9999999ZZ
Ingred Name:ING 11: DECOMP PRODS DURING WELDING & FLAME CUTTING ON
SURFS COATED W/PROD. VAPS MAY SPREAD LONG DISTANCES. (ING 13)
RTECS #:9999999ZZ
Ingred Name:ING 12: PREVENT BUILDUP BY REMOVING HEAVY SOLV VAPS FROM
LOWER LEVELS OF WORK AREA. ELIMINATE ALL IGNITION SOURCES.
RTECS #:9999999ZZ
Ingred Name:AMINE COMPOUND LD50: (ORAL, RAT) 5 G/KG
Fraction by Wt: 70%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:BUTYL ALCOHOL; (N-BUTYL ALCOHOL) (SARA 313) (CERCLA). VP:
4.2. LD50: (ORAL, RAT) 2.5 G/KG
CAS:71-36-3
RTECS #:EO1400000
Fraction by Wt: 30%
OSHA PEL:100 PPM
ACGIH TLV:50 PPM, S, C
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:VOLATILE ORGANIC COMPOUND: 265.50 G/L
RTECS #:9999999VO
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:SUPDAT: NOT BE IMMEDIATELY APPARENT. OBTAIN MEDICAL
ATTENTION.
RTECS #:9999999ZZ
Ingred Name:SPILL PROC: NON-SPARKING TOOLS. STORE IN CLOSED CONTAINER
UNTIL PROPERLY DISPOSED OF.
RTECS #:9999999ZZ
Ingred Name:HNDLG/STOR PRECS: NEAR FIRE OR OPEN FLAME. STORE LG QTYS IN
BLDGS TO COMPLY W/OSHA 1910.106. KEEP CNTNR CLSD (ING 7)
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: IRRIT OF RESP TRACT;
HEADACHE, NAUSEA, DIZZINESS, WEAKNESS & FATIGUE. EXTREME EXPOS CAN
RESULT IN UNCON & EVEN RESP ARREST. SKIN/EYE CONTACT: CAUSES EYE &
SKIN IRRIT. MAY BE HARMFUL IF A BSORBED THRU SKIN. INGEST: CAN
CAUSE STOMACH &/OR INTESTINAL IRRIT, NAUSEA, VOMITING & DIARRHEA.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: INTENTIONAL MISUSE BY DELIB
CONCENTRATING & INHALING THE CONTENTS MAY BE HARMFUL/FATAL.
CHRONIC: REPORTS HAVE ASSOC RPTD & PRLNG OCCUP OVEREXP TO SOLVENTS
W/PERM BRAIN & NERVOUS SYSTEM DAMAG E. PRLNG/RPTD BREATHING OF
SPRAY MIST &/OR SANDING DUST OVER A PERIOD OF YEARS MAY CAUSE
CHRONIC DISEASE OF THE LUNGS.
Medical Cond Aggravated by Exposure:NONE, WHEN USED IN ACCORDANCE WITH
SAFE HANDLING AND USE INFORMATION.
======================= First Aid Measures =======================
First Aid:INHAL: IF BRTHG DFCLTY EXPERIENCED, LEAVE AREA TO OBTAIN
FRESH AIR. IF DFCLTY CONTINUES, SUMMON MED ASSISTANCE IMMED. IF
BRTHG CEASES, RESTORE USING APPRVD CPR TECHNIQUES & SUMMON MED HELP
IMMED. EYES : FLUSH IMMED W/LG AMTS OF WATER FOR ATLEAST 15 MIN.
GET MED ASSISTANCE. SKIN: WASH AFFECTED AREA W/SOAP & WATER. REMOVE
SOILED CLTHG. GET MED ASSISTANCE IF IRRIT PERSISTS. INGEST: CONSULT
MD IMMED.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:100F,38C
Lower Limits:1.4%
Extinguishing Media:IN CASE OF FIRE, USE CARBON DIOXIDE, DRY CHEMICAL,
FOAM OR OTHER NFPA APPROVED METHOD FOR TREATING CLASS B FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZS PREF. IF
EXPOS TO FIRE/EXTREME HEAT, WATER (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPK & FLAME. DUE TO PRESS BUILD-UP, CLSD CNTNRS
EXPOS TO EXTREME HEAT MAY EXPLODE. NEVER USE (SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT (FLAMES, HOT SURFS
& ELEC, STATIC/FRICTIONAL SPKS). PVNT BRTHG OF VAPS. VENT AREA.
BEFORE ATTEMPTING CLEANUP, REFER TO HAZ CAUTION INFO IN OTHER
SECTIONS OF MSDS. CONTAIN S PILLED MATL & REMOVE W/INERT ABSORB &
(ING 5)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPK & FLAMES. DO
NOT SMOKE. PVNT BUILDUP OF VAPS BY MAINTAINING CONTINUOUS FLOW OF
FRESH AIR. DO NOT STORE ABOVE 120F OR (ING 6)
Other Precautions:DO NOT TRANSFER CONTENTS TO BOTTLES OR OTHER
UNLABELLED CNTNRS. DO NOT REUSE EMPTY CNTNRS. IF MATL IS PART OF
TWO COMPONENT PROD, THEN MIXTURE OF BASE & CONVERTER PORTIONS WILL
HAVE HAZS OF BOTH. OBSE RVE ALL APPLICABLE PRECAUTIONS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:DO NOT BREATHE VAPS, SPRAY MIST/SANDING DUST.
WHEN SPRAY APPLIED IN OUTDOOR/OPEN AREAS & DURING SANDING/GRINDING
OPERATIONS, USE NIOSH/MSHA APPRVD MECH FILTER RESP TO REMOVE SOLID
AIRBORNE PARTICLES O F OVERSPRAY & SANDING DUST. (ING 8)
Ventilation:PROVIDE GEN DILUTION OR LOC EXHST VENT IN VOL & PATTERN TO
KEEP AIR CONTAMINANT CONC BELOW CURRENT APPLIC (ING 11)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:DO NOT GET ON SKIN. SOLVENT IMPERMEABLE
CLOTHING & BOOTS TO PREVENT SKIN CONTACT ARE RECOMMENDED.
Work Hygienic Practices:REMOVE AND WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: PRIMER, NON-SLIP CLEAR. FIRE FIGHT PROC:
SHOULD BE USED TO COOL CLSD CNTNRS & PVNT PRESS BUILDUP OR POSS
AUTOIGNIT. EXPLO HAZS: WELDING/CUTTING TORCH ON/NEAR CNTNR (EVEN
EMPT Y) AS PROD/ITS RESIDUE MAY IGNITE. DURING EMER CNDTNS OVEREXP
TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY (ING 4)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:244F,118C
Vapor Pres:SEE ING 2
Vapor Density:HVR/AIR
Spec Gravity:0.948
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:32.79
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMP. FUMES MAY CONTAIN CARBON MONOXIDE, CARBON DIOXIDE, OXIDES
OF NITROGEN.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.