J. T. BAKER INC. -- ACETALDEHYDE -- -
=====================  Product Identification  =====================

Product ID:ACETALDEHYDE
MSDS Date:10/08/1996
FSC:NIIN:Submitter:D DG
Status Code:A
MSDS Number: CKTXB
=== Responsible Party ===
Company Name:J. T. BAKER INC.
Address:222 RED SCHOOL LANE
City:PHILLIPSBURG
State:NJ
ZIP:08865-2219
Country:US
Info Phone Num:908-859-2151/ 800-582-2537
Emergency Phone Num:201-859-2151
Chemtrec Ind/Phone:(800)424-9300
CAGE:70829
=== Contractor Identification ===
Company Name:MALLINCKRODT BAKER,  INC.
Address:222 RED SCHOOL LANE
Box:City:PHILLIPSBURG
State:NJ
ZIP:08865
Country:US
Phone:800-582-2537
Contract Num:MDA414-OO-P-4900
CAGE:70829

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETALDEHYDE
CAS:75-07-0
RTECS #:AB1925000
Minumum % Wt:90.
Maxumum % Wt:100.
OSHA PEL:360 MG/M3;200 PPM
ACGIH STEL:C45 MG/M3;C25 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: RESPIRATORY SYSTEM,
    LIVER, KIDNEY, BLOOD, LUNGS, SKIN, CNS.  INHALATION: IRRITATION OF
    MUCOUS MEMBRANES, CENTRAL NERVOUS SYSTEM DEPRESSION, SEVERE
    IRRITATION OF RESPIRATORY SYSTEM, PULM ONARY EDEMA,
    UNCONSCIOUSNESS. SKIN: IRRITATION, PROLONGED CONTACT MAY CAUSE
    DERMATITIS. EYES: SEVERE IRRITATION OR BURNS, MAY CAUSE TEMPORARY
    CORNEAL DAMAGE. INGESTION:GASTROINTESTINAL IRRITATION, CEN TRAL
    NERVOUS SYSTEM DEPRESSION, SEVERE BURNS TO MOUTH, THROAT, AND
    STOMACH, RESPIRATORY FAILURE, UNCONSCIOUSNESS. CHRONIC EFFECTS:
    CENTRAL NERVOUS SYSTEM DEPRESSION, DAMAGE TO LIVER, KIDNEYS, AND
    BLOO D.
Explanation of Carcinogenicity:THIS SUBSTANCE IS LISTED AS AN IARC
    ANIMAL CARCINOGEN.	PER HMIS: IARC 2B CLASSIFICATION- THE AGENT IS
    POSSIBLE CARCINOGENIC TO HUMANS; THERE IS LIMITED EVIDENCE OF
    CARCINOGENICITY SUFFICIENT EVIDENCE  OF CARCINOGENICITY IN
    EXPERIMENTAL ANIMALS.  NTP- REASONABLY ANTICIPATED TO BE
    CARCINOGENS.
Effects of Overexposure:NHALATION: IRRITATION OF MUCOUS MEMBRANES,
    HEADACHE, NAUSEA, VOMITING, DIZZINESS, DROWSINESS,	AND NARCOSIS.  
    SKIN CONTACT: IRRITATION. EYE CONTACT: SEVERE IRRITATION OR BURNS.
    SKIN ABSORPTION: NONE  IDENTIFIED. INGESTION: HEADACHE, NAUSEA,
    VOMITING, DIZZINESS, GASTROINTESTIONAL IRRITATION, SEVERE BURNS TO
    MOUTH, THROAT, AND STOMACH.
Medical Cond Aggravated by Exposure:NONE IDENTIFIED

=======================  First Aid Measures  =======================

First Aid:INGESTION: CALL A PHYSICIAN. IF SWALLOWED, IF CONSCIOUS, GIVE
    LARGE AMOUNTS OF WATER. INDUCE VOMITING. INHALATION: IF INHALED,
    REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTFICIAL RESPIRATION.
    IF BRE ATHING IS DIFFICULT, GIVE OXYGEN. PROMPT ACTION IS
    ESSENTIAL. SKIN CONTACT: IN CASE OF CONTACT, IMMEDIATELY FLUSH SKIN
    WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES WHILE REMOVING
    CONTAMINATED CLOTHING  AND HOES. WASH CLOTHING BEFORE RE-USE. EYE
    CONTACT: IN CASE OF EYE CONTACT, IMMEDIATELY FLUSH WITH PLENTY OF
    WATER FOR AT LEAST 15 MINUTES.

=====================  Fire Fighting Measures  =====================

Flash Point:=-37.C, -34.6F
Autoignition Temp:=174.C, 345.2F
Lower Limits:4.0
Upper Limits:60.0
Extinguishing Media:USE ALCOHOL FOAM, DRY CHEMICAL OR CARBON DIOXIDE.
    (WATER MAY BE INEFFECTIVE).
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR PROPER PROTECTIVE
    EQUIPMENT AND SELF-CONTAINED BREATHING APPARATUS WITH FULL
    FACEPIECE OPERATED IN POSITIVE PRESSURE MODE. MOVE CONTAINES FROM
    FIRE AREA IF IT CAN BE DONE WITH OUT RISK. USE WATER TO KEEP
    FIRE-EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:VAPORS MAY FLOW ALONG SURFACES TO DISTANT
    IGNITION SOURCES AND FALSH BACK. CLOSED CONTAINERS EXPOSED TO HEAT
    MAY EXPLODE. CONTACT WITH STRONG OXIDIZERS MAY CAUSE FIRE. RAPID,
    UNCONTROLLED POLYMERIZATI ON CAN CAUSE FIRE OR EXPLOSION. MAY FORM
    EXPLOSIVE PEROXIDES, ESPECIALLY WHEN HEATED.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS & FULL
    PROTECTIVE CLOTHING. SHUT OFF IGNITION SOURCES; NO FLARES, SMOKING,
    FLAMES. STOP LEAK IF YOU CAN DO SO WITHOUT RISK. USE WATER SPRAY TO
    REDUCE VAPORS. TA KE UP WITH SAND/ OTHER NON-COMBUSTIBLE ABSORBENT
    MATERIAL AND PLACE INTO CONTAINER FOR LATER DISPOSAL. FLUSH AREA
    WITH WATER. SOLUSORB(R)  SOLVENT ABSORBENT IS RECOMMENDED FOR
    SPILLS OF THIS PRODUCT.

======================	Handling and Storage  ======================

Handling and Storage Precautions:SAF-T-DATA STORAGE COLOR CODE: RED
    STRIPE (STORE SEPERATELY)  STORAGE REQUIREMENTS: KEEP CONTAINER
    TIGHTLY CLOSED. STORE IN A COOL, DRY, WELL-VENTILATED, FLAMMABLE
    LIQUID STORAGE AREA. PRODUCT MUST BE  REFRIGERATED AT 2-8 C (36-46
    F).  ISOLATE FROM INCOMPATIBLE MATERIALS.
Other Precautions:BOND AND GROUND CONTAINERS WHEN TRANSFERRING	LIQUID.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:RESPIRATORY PROTECTION REQUIRED IF AIRBORNE
    CONCENTRATION EXCEEDS TLV. AT CONCENTRATIONS UP TO 1000 PPM, A
    CHEMICAL CARTRIDGE RESPIRATOR WITH ORGANIC VAPOR CARTRIDGE IS
    RECOMMENDED. ABOVE THIS LEVEL,  A SELF-CONTAINED BREATHING
    APPARATUS IS RECOMMENDED.
Ventilation:USE GENERAL OR LOCAL EXHAUST VENTILATION TO MEET TLV
    REQUIREMENTS.
Protective Gloves:RUBBER GLOVES.
Eye Protection:SAFETY GOGGLES.
Other Protective Equipment:UNIFORM, APRON.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:F1
Boiling Pt:=20.C, 68.F
Melt/Freeze Pt:=-124.C, -191.2F
Vapor Pres:750 MM HG @ 20C
Vapor Density:1.52
Appearance and Odor:CLEAR, COLORLESS LIQUID.  PUNGENT ODOR.
Percent Volatiles by Volume:100 @ 21C

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG BASES, AMINES AND AMMONIA, STRONG
    ACIDS, POLYMERIZATION CATALYSTS & ACCELERATORS, ACID ANHYDRIDES,
    ALCOHOLS, KETONES, PHENOLS, HALOGENS, HYDROGEN CYANIDE, HYDROGEN
    SULFIDE.
Stability Condition to Avoid:HEAT, FLAME, OTHER SOURCES OF IGNITION,
    AIR.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
    EXPLOSIVE PEROXIDES.
Conditions to Avoid Polymerization:HAZARDOUS POLYMERIZATION: MAY OCCUR.

===================  Toxicological Information	===================

Toxicological Information:REPRODUCTIVE EFFECTS: TESTS ON LABORATORY
    ANIMALS INDICATE MATERIAL MAY BE MUTAGENIC AND TERATOGENIC.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE
    FEDERAL, STATE, AND LOCAL ENVIRONMENTAL REGULATIONS. EPA HAZARDOUS
    WASTE NUMBER: U001 (TOXIC WASTE).

===================  MSDS Transport Information  ===================

Transport Information:DOT, IMO, & ICAO: ACETALDEHYDE, 3, UN1089, PG I.

=====================  Regulatory Information  =====================

SARA Title III Information:SARA 313 TOXIC CHEMICALS: YES, CONTAINS
    ACETALDEHYDE.  SARA/TITLE III HAZARD CATEGORIES AND LISTS- ACUTE:
    YES. CHRONIC: YES. FLAMMABLILITY: YES.  PRESSURE: NO.  REACTIVITY:
    YES.  EXTREMELY HAZARDOUS S UBSTANCE: NO.
Federal Regulatory Information:TSCA INVENTORY: YES.
State Regulatory Information:FOR PRODUCTS SOLD IN THE STATE OF
    CALIFORNIA, THE STATE REQUIRES THAT WE PROVIDE TO USERS AND THEIR
    EMPLOYEES THE FOLLOWING MESSAGE: WARNING: THIS PRODUCT IS A
    CHEMICAL KNOWN TO THE STATE OF CALIFORNI A TO CAUSE CANCER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.