DEXSIL CHEMICAL CORP           -- CLOR-D-TECT 1000; AMPULE 6 (AQUEOUS SOLUTION)
=======================================================
MSDS Safety Information 
=======================================================
FSC: 6850
NIIN: 01-316-9398
MSDS Date: 05/17/1995
MSDS Num: BSVRJ
Product ID: CLOR-D-TECT 1000; AMPULE 6 (AQUEOUS SOLUTION)
MFN: 06
Kit Part: Y
Responsible Party
Cage: 65297
Name: DEXSIL CHEMICAL CORP
Address: 1 HAMDEN PARK DRIVE
City: HAMDEN CT 06514-3150
Info Phone Number: 203-288-3509
Emergency Phone Number: 203-288-3509, CHEMTREC 800-424-9300
Preparer's Name: UNKNOWN
Proprietary Ind: Y
Review Ind: Y
Published: Y
=======================================================
Contractor Summary 
=======================================================
Cage: 65297
Name: DEXSIL CORP
Address: 1 HAMDEN PARK DR
City: HAMDEN CT 06514-3150
Phone: 203-288-3509
=======================================================
Item Description Information 
=======================================================
Item Manager: S9G
Item Name: DETECTION KIT,CHLORINATED SOLVENTS
Unit of Issue: BG
Quantitative Expression: 00000000020EA
UI Container Qty: 1
Type of Container: BAG
=======================================================
Ingredients 
=======================================================
Name: *** PROPRIETARY  ***
-----------------------------
=======================================================
Health Hazards Data 
=======================================================
LD50 LC50 Mixture: UNKNOWN
Route Of Entry Inds - Inhalation: NO
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: YES
IARC: YES
OSHA: NO
Effects of Exposure: CORROSIVE TO ALL TISSUES. THIS PRODUCT CAN CAUSE SEVERE
  INJURY IF IMPROPERLY HANDLED OR THE KNOWN DANGERS OF USE ARE NOT HEEDED.
Explanation Of Carcinogenicity: THIS PRODUCT CONTAINS CADMIUM, LISYED AS A NTP
  ANTICIPATED CARCINOGEN AND AN IARC PROBABLE HUMAN CARCINOGEN (2A AND 2B)
Signs And Symptions Of Overexposure: USER SHOULD RECOGNIZE THIS PRODUCT CAN
  CAUSE SEVERE INJURY AND EVEN DEATH IF IMPROPERLY HANDLED.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYES- FLUSH WITH LARGE AMOUNTS OF WATER 15 MINUTES. SEEK MEDICAL
  ATTENTION. SKIN- FLUSH WITH LARGE AMOUNTS OF WATER. USE SOAP AND WATER TO
  WASH AWAY ORGANIC COMPONENTS. INHALATION- REMOVE TO FRESH AIR .
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: ABSORB COMPLETELY IN INERT ABSORBENT, NEUTRALIZE WITH
  SODA BICARB SOLUTION. FLUSH AREA WITH WATER.
Neutralizing Agent: 5% SOLUTION OF SODIUM BICARBONATE. ()
Waste Disposal Methods: DISP0SE OF IN ACCORDANCE WITH ALL APPLICALBE FEDERAL,
  STATE AND LOCAL ENVIRONMENTAL REGULATIONS.
Handling And Storage Precautions: STORE KIT IN A COOL, DRY PLACE. CHECK
  EXPIRATION DATE PRIOR TO PERFORMING TEST.
Other Precautions: WEAR APPROPRIATE SAFETY EQUIPMENT WHEN PERFORMING THE TEST
  ON SITE.
=======================================================
Fire and Explosion Hazard Information 
=======================================================
Flash Point Text: NONE
Extinguishing Media: DO NOT USE WATER ON A SODIUM FIRE. DRY CHEMICAL, FOAM,
  CARBON DIOXIDE.
Fire Fighting Procedures: DO NOT USE WATER. WEAR SCBA. AVOID BREATHING TOXIC
  FUMES.
Unusual Fire/Explosion Hazard: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Control Measures 
=======================================================
Respiratory Protection: DEPENDING ON USAGE, RESPIRATORS MUST BE USED TO AVOID
  CONTACT WITH MATERIAL OR BREATHING CHEMICAL VAPORS/FUMES.
Ventilation: PERFORM TEST ONLY IN A WELL VENTILATED AREA.
Protective Gloves: ALWAYS WEAR RUBBER GLOVES.
Eye Protection: SAFETY GLASSES.
Other Protective Equipment: WEAR APPROPRIATE SAFETY EQUIPMENT WHEN PERFORMING
  TEST ON SITE.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: KEY1:C1. THIS MSDS IS FOR AMPULE CONTAINING
  AQUEOUS SOLUTION OF 3% SULFURIC ACID (PH 1.1). FOR AMPULE 1, 2, 3, 4, AND 5
  SEE PNI A, B, C, D, AND E, SAME NSN.
=======================================================
Physical/Chemical Properties 
=======================================================
HCC: R2
B.P. Text: >212F,>100C
Vapor Pres: 16 MM HG
Spec Gravity: 1.09
PH: 1.1
Viscosity: NOT RELEVANT
Solubility in Water: COMPLETE
Appearance and Odor: COLORLESS.
Percent Volatiles by Volume: NONE
=======================================================
Reactivity Data 
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products: NONE SPECIFIED BY MANUFACTURER.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information 
=======================================================
=======================================================
Ecological Information 
=======================================================
=======================================================
MSDS Transport Information 
=======================================================
=======================================================
Regulatory Information 
=======================================================
=======================================================
Other Information 
=======================================================
=======================================================
Transportation Information 
=======================================================
Responsible Party Cage: 65297
Trans ID NO: 124861
Product ID: CLOR-D-TECT 1000; AMPULE 6 (AQUEOUS SOLUTION)
MSDS Prepared Date: 05/17/1995
Review Date: 08/07/1995
MFN: 6
Tech Entry NOS Shipping Nm: SULFURIC ACID (7 ML OF 3% SOLN.); <0.05% CADMIUM
Multiple KIT Number: 0
Kit Part IND: Y
Review IND: Y
Unit Of Issue: BG
Container QTY: 1
Type Of Container: BAG
Additional Data: THIS ITEM IS SMALL QUANTITY. REF. 49 CFR 173.4 EXCEPTIONS FOR
  SMALL QUANTITIES. TOTAL KIT SHIPPED AS :  PSN-ALKALI METAL DISPERSIONS;
  HAZARD CLASS-4.3; UN 1391; PACKING GROUP 1. SEE THIS NSN AND PN IND A, B, C,
  D, AND E FOR ADDITIONAL INFORMATION.
=======================================================
Detail DOT Information 
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information 
=======================================================
IMO PSN Code: ESC
IMO Proper Shipping Name: CORROSIVE LIQUID, TOXIC, N.O.S. o
IMDG Page Number: 8149
UN Number: 2922
UN Hazard Class: 8
IMO Packaging Group: I/II/III
Subsidiary Risk Label: TOXIC
EMS Number: 8-15
MED First Aid Guide NUM: 760
=======================================================
Detail IATA Information 
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information 
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label 
=======================================================
Product ID: CLOR-D-TECT 1000; AMPULE 6 (AQUEOUS SOLUTION)
Cage: 65297
Company Name: DEXSIL CORP
Street: 1 HAMDEN PARK DR
City: HAMDEN CT
Zipcode: 06514-3150
Health Emergency Phone: 203-288-3509, CHEMTREC 800-424-9300
Label Required IND: Y
Date Of Label Review: 08/02/1995
Status Code: C
MFG Label NO: NOT RELEVANT
Label Date: 08/02/1995
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: CORROSIVE TO ALL TISSUES. THIS PRODUCT CAN CAUSE SEVERE
  INJURY IF IMPROPERLY HANDLED OR THE KNOWN DANGERS OF USE ARE NOT HEEDED.
  STORE KIT IN A COOL, DRY PLACE. CHECK EXPIRATION DATE PRIOR TO PERFORMI NG
  TEST. FIRST AID: EYES- FLUSH WITH LARGE AMOUNTS OF WATER 15 MINUTES. SEEK
  MEDICAL ATTENTION. SKIN- FLUSH WITH LARGE AMOUNTS OF WATER. USE SOAP AND
  WATER TO WASH AWAY ORGANIC COMPONENTS. INHALATION-  REMOVE TO FRESH AIR.
  TARGET ORGANS: SKIN, EYES.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
  information is formulated for use by elements of the Department of Defense.
  The United States of America in no manner whatsoever expressly or implied
  warrants, states, or intends said information to have any application, use or
  viability by or to any person or persons outside the Department of Defense
  nor any person or persons contracting with any instrumentality of the United
  States of America and disclaims all liability for such use. Any person
  utilizing this instruction who is not a military or civilian employee of the
  United States of America should seek competent professional advice to verify
  and assume responsibility for the suitability of this information to their
  particular situation regardless of similarity to a corresponding Department
  of Defense or other government situation.